1300 WACV (PWR C45-1300ACV) |
2800 WACV (PWR C45 2800ACV) |
1400 WDC-P (PWR C45-1400DC-P) |
4200 WACV PWR C45-4200ACV) |
6000 WACV (PWR-C45-6000ACV) |
2500W (PWR-4502) |
Minimum Cisco IOS® Software Release required |
12.1(12c)EW |
12.1(12c)EW |
12.1(13)EW |
12.2 |
12.2(52)SG |
12.1(13)EW |
Minimum Cisco Catalyst Operating System Software required |
7.4(1) |
7.4(1) |
7.5(1) |
- |
- |
7.5(1) |
Integrated PoE |
Yes (up to 800W) |
Yes (up to 1400W) |
Up to 7500W (minus power consumed for data) when connected directly to DC power plant or 2 external AC power shelves |
Yes (up to 3855W) |
Yes (up to 4800W) |
2500W per power supply |
IEEE 802.3af compliant |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Input current (rated) |
16A at 100 VAC
7A at 240 VAC |
16A at 200 VAC |
Data: 31A at -60 VDC
Inline: 180A at -48VDC |
Two 12A at 100 VAC or
Two 12A at 200 VAC |
Two 12A at 100 VAC or
Two 16A at 200 VAC |
15A at 200 VAC |
Output current (data) |
12V at 84.7A
3.3V at 12.5A |
12V at 113.3A
3.3V at 12.1A |
12V at 120A
3.3V at 10A |
12V at 115.3A
3.3V at 12.5A |
12V at 186.9A
3.3V at 12.5A |
-52 VDC at 50A (total output per supply) |
Output current (PoE) |
-50V at 16.7A |
-50V at 28A |
-48 or -60 VDC at 140A |
-50V at 77.1A (200V)
-50V at 38A (100V) |
-50V at 100.0A (200V)
-50V at 38.5A (120V) |
-52 VDC at 50A (total output per supply) |
Output power redundant mode (data) |
1000W + 40W |
1360W + 40W |
1367W + 40W |
1383W + 40W |
2200W + 40W |
Up to 1400W (through DC supply) |
Output power redundant mode (PoE) |
800W maximum per power supply |
1400W maximum per power supply |
Up to 7500W (minus the power consumed for data) |
3700W (220V)
1850W (110V) |
4800W (220V)
1850W (110V) |
2500W per supply (minus the power consumed for data) |
Output power combined mode (data) |
1667W |
2473W |
2734W |
2766W |
4400W |
1360W |
Output power combined mode (PoE) |
1333W (maximum) |
2333W |
7280W |
6700W (220V)
3360W (110V) |
8700W (220V)
3360W (110V) |
- |
Heat dissipation |
1568 BTU/hour |
2387 BTU/hr |
Data only: 1591 BTU/hr
Data and voice: 2905 BTU/hr |
3580 BTU/hr |
2720 BTU/hr |
1210 BTU/hr per power supply |
Holdup time |
20 ms |
20 ms |
4 ms |
20 ms |
20 ms |
20 ms |
Number of 802.3af class 2 powered devices supported |
106 |
186 |
384 |
384 (200V)
245 (100V) |
384 (200V)
245 (100V) |
318 (per unit) |
Number of 802.3af classes 0 and 3 powered devices supported |
48 |
84 |
384 |
223 (200V)
111 (100V) |
289 (200V)
111 (100V) |
144 (per unit) |